Solutions for Industries and Automation
 
ABB Measurement and Analytics - Quad Industry GmbH

FCB430 and FCB450 – Coriolis mass flowmeter CoriolisMaster

CoriolisMaster FCB400 series of compact Coriolis mass flowmeters feature low pressure drop, high capacity, 9IBA195751_400x400intuitive ABB common display, five modular I/O`s and HART communication.

Overview

With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.

The FCB400 series delivers: 

  • Up to five modular I/Os
    – Multivariable meter design
    – Optional plug-in cards
    – Automatic firmware update
  • SmartSensor
    – All digital solution
    – Installation flexibility
    – Meter intelligence located in the sensor
  • SensorApplicationMemory
    – Maximum data security
    – Plug and play electronics replacement
  • ABB common look and feel
    – Easy Set-up
    – Operation through the glass via capacitive keys
  • VeriMass on-board verification and diagnostics
    – Online preventive maintenance
    – Extended maintenance cycles
    – Reduced maintenance effort
  • Designed for 70 °C (158 °F) ambient temperature and high vibrations
  • Lower pressure drop
  • Self-draining
  • Global approvals for explosion protection

The FCB450 adds:

  • DensiMass software for direct concentration measurement
  • FillMass software for filling application control

 

Data

General specifications:

  • Nominal sizes / measuring ranges
    – DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
    – DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
    – DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
    – DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
    – DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
    – DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h)
  • Ex approvals
    – ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
  • Wetted materials
    – 1.4404 / 1.4435 (316L) or Hasteloy C
  • Accuracy for liquids
    FCB430
    – Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
    – Density: 10 g/l
    FCB450
    – Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
    – Density: 2 g/l or 1 g/l
  • Measuring medium temperature
    FCB430
    –  -50 to 160 °C (-58 to 320 °F)
    FCB450
    –  -50 to 205 °C (-58 to 400 °F)
  • Outputs
    – 5 modular I/Os
    – HART 7.1
    – PROFIBUS DP
    – Modbus
  • Power supply
    – 11 to 30 V DC, 110/230 V AC

Catalog and Questionnaire List

DS_FCB400_FCH400_EN_K.pdf