{"id":897,"date":"2021-01-01T20:13:50","date_gmt":"2021-01-01T20:13:50","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=897"},"modified":"2021-01-01T20:13:50","modified_gmt":"2021-01-01T20:13:50","slug":"el3060-abb-easyline-for-hazardous-locations","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=897","title":{"rendered":"EL3060 &#8211; ABB EasyLine for hazardous locations"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\" wp-image-899 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3060.jpg\" alt=\"EL3060\" width=\"355\" height=\"352\" \/>The <span style=\"color: #ff0000;\">ABB EL3060<\/span> series is compactly built\u00a0and especially designed for hazardous areas. The gas analyzer is made up of the flameproof enclosed control unit which can also contain one analyzer<\/p>\n<div class=\"sfContentBlock\">\n<p><strong>The specialists for hazardous locations <\/strong><\/p>\n<div>The EL3060 series is compactly built and especially designed for hazardous areas.The gas analyzer is made up of the flameproof enclosed control unit which can also contain one analyzer. The infrared\u00a0photometer is built into a separate flameproof enclosure and can be separately installed from the control unit. Their robust and flameproof design meets the requirements for use in hazardous areas, Zone 1, Category 2G in accordance with European ATEX legislation. Their display with touch screen renders safe operation without opening the housing.<\/div>\n<p><strong>Well-proven measurement technology<\/strong><br \/>\nThe analyzers for the EL3060 have been taken from the modular product line Advance Optima where they have been successfully used in process analytics for many years.<\/p>\n<div>\n<ul>\n<li>Infrared photometer Uras26<\/li>\n<li>Paramagnetic oxygen analyzers Magnos206, Magnos28<\/li>\n<li>Thermal conductivity analyzers Caldos27, Caldos25<\/li>\n<\/ul>\n<div><strong>Easy to Combine<\/strong><\/div>\n<p>An oxygen as well as the thermal conductivity analyzer can be combined with the Infrared Photometer. This means that complex measuring tasks like internal cross sensivity corrections with up to 5 measuring components in one device can be fulfilled.<\/p>\n<div><strong>Advantages EL3060<\/strong><\/div>\n<ul>\n<li>Well-proven measurement technology<\/li>\n<li>Compactly built, easy to combine<\/li>\n<li>Intuitiv menu, safe touch screen operation<\/li>\n<li>Easy to install<\/li>\n<li>Proved standard interfaces, Modbus, PROFIBUS<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div class=\"lo_colsOut lo_2cols_1_67\">\n<div class=\"lo_colsIn lo_2cols_1in_67\">\n<div class=\"sf_cols\">\n<div class=\"sf_colsOut sf_1col_1_100\">\n<div id=\"Content_C049_Col00\" class=\"sf_colsIn sf_1col_1in_100 layout8\">\n<div class=\"sfContentBlock\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Infrared-Photometer Uras26<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<th valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"189\"><strong>Measuring component<\/strong><\/th>\n<td width=\"189\"><strong>Smallest measuring range<\/strong><\/td>\n<td width=\"340\"><strong>Information<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">CO<\/td>\n<td width=\"189\">0&#8230;10 ppm<\/td>\n<td rowspan=\"4\" width=\"340\">Other approved components and measuring ranges described in the data sheet<br \/>\n2 measuring ranges per measuring component which can be freely selected<br \/>\n4 measuring components<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">CO<sub>2 <\/sub><\/td>\n<td width=\"189\">0&#8230;5 ppm<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">SO<sub>2<\/sub><\/td>\n<td width=\"189\">0&#8230;25 ppm<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">NO<\/td>\n<td width=\"189\">0&#8230;75 ppm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Oxygen Analyzer Magnos28<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"718\"><strong>Measuring component<\/strong><\/td>\n<td width=\"718\"><strong>Smallest measuring range<\/strong><\/td>\n<td width=\"718\"><strong>Information<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"718\">O<sub>2<\/sub><\/td>\n<td width=\"718\">0&#8230;0,5 Vol%<\/td>\n<td width=\"718\">2 measuring ranges per measuring component which can be freely selected<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Oxygen Analyzer Magnos206<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<th valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"189\"><strong>Measuring component<\/strong><\/th>\n<td width=\"189\"><strong>Smallest measuring range<\/strong><\/td>\n<td width=\"340\"><strong>Information<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"189\">O<sub>2 <\/sub><\/td>\n<td width=\"189\">0&#8230;0,5 Vol%<\/td>\n<td width=\"340\">2 measuring ranges per measuring component which can be freely selected<br \/>\nSuppressed measuring ranges e.g. 19\u202621 Vol% O<sub>2<\/sub>, Suppressed range max. 1:10<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Thermal Conductivity Caldos25<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<th valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"189\"><strong>Measuring component<\/strong><\/th>\n<td width=\"189\"><strong>Smallest measuring range<\/strong><\/td>\n<td width=\"340\"><strong>Information<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">H<sub>2<\/sub> in N<sub>2<\/sub> or in Air<\/td>\n<td width=\"189\">0&#8230;10 ppm<\/td>\n<td rowspan=\"2\" width=\"340\">1 measuring range per measuring component<br \/>\n3 measuring components<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">SO<sub>2<\/sub> in N<sub>2<\/sub> or in Air<\/td>\n<td width=\"189\">0&#8230;5 ppm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Thermal Conductivity Caldos27<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<th valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"189\"><strong>Measuring component<\/strong><\/th>\n<td width=\"189\"><strong>Smallest measuring range<\/strong><\/td>\n<td width=\"340\"><strong>Information<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">H<sub>2<\/sub> in Air<\/td>\n<td width=\"189\">0&#8230;1 Vol%<\/td>\n<td rowspan=\"4\" width=\"340\">For other components and measuring ranges please refer to the Data sheet<\/p>\n<p>2 measuring ranges per measuring component<br \/>\n4 measuring components<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"189\">H<sub>2<\/sub> in N<sub>2<\/sub><\/td>\n<td width=\"189\">0&#8230;1 Vol%<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"189\">He in Air<\/td>\n<td width=\"189\">0&#8230;2 Vol<\/td>\n<\/tr>\n<tr valign=\"top\">\n<td valign=\"middle\" width=\"189\">CH<sub>4<\/sub> in H<sub>2<\/sub><\/td>\n<td width=\"189\">0&#8230;3 Vol%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col \/>\n<col \/>\n<col \/><\/colgroup>\n<tbody>\n<tr valign=\"top\">\n<td colspan=\"3\" width=\"718\"><span style=\"color: #ff0000;\"><strong>Certification<\/strong><\/span><\/td>\n<\/tr>\n<tr valign=\"top\">\n<th valign=\"middle\" bgcolor=\"#e1e1e1\" width=\"189\"><strong>Ex-Certificate<\/strong><\/th>\n<td width=\"189\"><strong>Material<\/strong><\/td>\n<td width=\"340\"><strong>Flameproof enclosure<\/strong><\/td>\n<\/tr>\n<tr valign=\"top\">\n<td width=\"189\">ATEX II 2G EEx de IIC T4<\/td>\n<td width=\"189\">Aluminium diecast<\/td>\n<td width=\"340\">Housing according to IEC\/EN 60079-1<br \/>\nTerminal box according to IEC\/EN 60079-7<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><span style=\"color: #ff0000;\"><strong>Catalog and Questionnaire List<\/strong><\/span><\/div>\n<div class=\"sfContentBlock\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-898 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/DS_EL3060_EN_B.pdf.jpg\" alt=\"DS_EL3060_EN_B.pdf\" width=\"90\" height=\"120\" \/><\/p>\n<div class=\"dsDocumentThumbnail\"><\/div>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_EL3060_EN_B.pdf\" target=\"_blank\">Data sheet &#8211; EasyLine EL3060 Series | Gas analyzers for use in hazardous areas<\/a><\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The ABB EL3060 series is compactly built\u00a0and especially designed for hazardous areas. The gas analyzer is made up of the flameproof enclosed control unit which can also contain one analyzer The specialists for hazardous locations The EL3060 series is compactly built and especially designed for hazardous areas.The gas analyzer is &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":882,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/897"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=897"}],"version-history":[{"count":1,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/897\/revisions"}],"predecessor-version":[{"id":900,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/897\/revisions\/900"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/882"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=897"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}