{"id":893,"date":"2021-01-01T20:09:12","date_gmt":"2021-01-01T20:09:12","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=893"},"modified":"2021-01-01T20:09:12","modified_gmt":"2021-01-01T20:09:12","slug":"el3000-abb-easyline-gas-analyzer","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=893","title":{"rendered":"EL3000 &#8211; ABB EasyLine Gas Analyzer"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-895 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3000.jpg\" alt=\"EL3000\" width=\"400\" height=\"400\" srcset=\"https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3000.jpg 400w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3000-150x150.jpg 150w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3000-300x300.jpg 300w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/EL3000-200x200.jpg 200w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/>Analyzers so smart, they&#8217;re simple &#8211; ABB&#8217;s entry line for continuous gas analyzers. Robust and reliable for measuring gas concentrations in numerous applications. EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous applications<\/p>\n<div class=\"sfContentBlock\">\n<div><strong>The advantages to you \u2013 EasyLine offers: <\/strong><\/div>\n<ul>\n<li>Flame Ionization Detector<\/li>\n<li>Proven analyzer technology<\/li>\n<li>Intuitiv operation via five buttons<\/li>\n<li>UV photometer<\/li>\n<li>Infrared photometer<\/li>\n<li>Paramagnetic oxygen analyzer<\/li>\n<li>Electrochemical oxygen sensor<\/li>\n<li>Thermal conductivity analyzer<\/li>\n<li>Trace oxygen analyzer<\/li>\n<li>Extensive self-diagnosis functions<\/li>\n<li>Internal QAL3 reporting option according EN 14181<\/li>\n<li>Web server included for easy read-out by Internet browsers<\/li>\n<li>First analyzers already meets the new European guideline EN\u00a015267<\/li>\n<li>19&#8243; wide for rack mounting<\/li>\n<li>Compact, purgeable IP65 enclosure for wall mounting<\/li>\n<\/ul>\n<div><strong>No need for test gas cylinders<\/strong><\/div>\n<p>Automatic calibration in combination with the superior ABB calibration cell technology in the photometer, no need for expensive test gas cylinders in most applications. Zero point with ambient air.<\/p>\n<ul>\n<li>Photometer can be equipped with calibration cell<\/li>\n<li>Long term stability proven<\/li>\n<li>Optional QAL3 card allows internal automatic surveillance of drift and precision during operation<\/li>\n<\/ul>\n<div><strong>Good combinations<\/strong><\/div>\n<p>Several types of analyzers are available:<br \/>\nCombination of different analyzers in one single housing provides optimum economic and operational efficiency for your application.<\/p>\n<ul>\n<li>IR photometer and electrochemical oxygen sensor<\/li>\n<li>IR photometer and paramagnetic oxygen analyzer<\/li>\n<li>IR photometer and thermal conductivity<\/li>\n<li>UV photometer and paramagnetic oxygen analyzer<\/li>\n<li>UV photometer and electrochemical oxygen sensor<\/li>\n<\/ul>\n<\/div>\n<p><strong><span style=\"color: #ff0000;\">Uras26 Infrared photometer<\/span><br \/>\nSample gas, typical range <\/strong><br \/>\nCO \u00a0\u00a0\u00a0\u00a0 0&#8230;100 ppm<br \/>\nCO2\u00a0\u00a0 \u00a00&#8230;100 ppm<br \/>\nCH4\u00a0\u00a0\u00a0\u00a00&#8230;100 ppm<br \/>\nSO2\u00a0\u00a0\u00a0 0&#8230;100 ppm<br \/>\nNO\u00a0\u00a0\u00a0\u00a0\u00a0 0. .150 ppm<br \/>\nO2\u00a0\u00a0\u00a0\u00a0\u00a0\u00a00&#8230;5 Vol%<\/p>\n<p><strong><span style=\"color: #ff0000;\">Limas23 Ultraviolet photometer<\/span><br \/>\nSample gas, typical range <\/strong><br \/>\nNO\u00a0\u00a0\u00a0\u00a0\u00a0 0&#8230;50 ppm<br \/>\nNO2\u00a0\u00a0\u00a0\u00a0 0&#8230;50 ppm<br \/>\nSO2\u00a0\u00a0\u00a0\u00a0 0&#8230;100 ppm<\/p>\n<p><strong><span style=\"color: #ff0000;\">Caldos27 Thermal conductivity analyzer<\/span><br \/>\nMore than 30 binary gas mixtures are configurable<br \/>\n<\/strong><br \/>\n<strong><span style=\"color: #ff0000;\">Magnos28 Paramagnetic oxygen analyzer\u00a0<\/span><br \/>\nwith microwing technology<br \/>\nSample gas, typical range\u00a0<\/strong><br \/>\nO2\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a00&#8230;2 Vol%<br \/>\nMeasurement range suppression max. 1:50 e.g. 98&#8230;100 Vol%<\/p>\n<p><strong><span style=\"color: #ff0000;\">Magnos206 Oxygen analyzer<\/span><br \/>\nMagn.-mechanic (dumbbell)<br \/>\nSample gas, typical range <\/strong><br \/>\nO2\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a00&#8230;2 Vol%<br \/>\nMeasurement range suppression max. 1:50 e.g. 98&#8230;100 Vol%<\/p>\n<p><strong><span style=\"color: #ff0000;\">ZO23 Trace Oxygen analyzer<\/span><br \/>\nZirconia dioxide cell<br \/>\nSample gas, typical range <\/strong><br \/>\nO2\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 0&#8230;1 ppm<\/p>\n<p><strong><span style=\"color: #ff0000;\">Fidas24 Flame Ionization Detector<\/span><br \/>\nSample gas, typical range <\/strong><br \/>\nHydrocarbons\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 0&#8230;10 ppm (C1) to 1 Vol.% (C1)<\/p>\n<p><strong>Typical applications <\/strong><br \/>\n\u2022\u00a0Emission measurement<br \/>\n\u2022 Combustion processes<br \/>\n\u2022 Blast furnace and converter gas analysis<br \/>\n\u2022 Turbogenerator monitoring<br \/>\n\u2022 Industrial gas filling<br \/>\n\u2022 Landfill gas monitoring<br \/>\n\u2022 Biofermenters<br \/>\n\u2022 Ambient air monitoring<br \/>\n\u2022 Silo monitoring<br \/>\n\u2022 O2 trace and purity measurement<br \/>\n\u2022 Warehouses and fruit storage<\/p>\n<p><span style=\"color: #ff0000;\"><strong>Catalog and Questionnaire List<\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-894 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2021\/01\/DS_EL3000_EN_B.pdf.jpg\" alt=\"DS_EL3000_EN_B.pdf\" width=\"90\" height=\"120\" \/><\/p>\n<div class=\"dsDocumentThumbnail\"><\/div>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_EL3000_EN_B.pdf\" target=\"_blank\">Data sheet &#8211; EasyLine EL3000 Series | Continuous gas analyzers<\/a><\/span><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Analyzers so smart, they&#8217;re simple &#8211; ABB&#8217;s entry line for continuous gas analyzers. Robust and reliable for measuring gas concentrations in numerous applications. EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous applications The advantages to you \u2013 EasyLine offers: Flame &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":882,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/893"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=893"}],"version-history":[{"count":1,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/893\/revisions"}],"predecessor-version":[{"id":896,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/893\/revisions\/896"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/882"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=893"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}