{"id":692,"date":"2020-12-26T19:51:59","date_gmt":"2020-12-26T19:51:59","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=692"},"modified":"2020-12-26T19:57:56","modified_gmt":"2020-12-26T19:57:56","slug":"ps45-abb-magnetic-level-gauge-switch","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=692","title":{"rendered":"PS45 &#8211; ABB Magnetic level gauge switch"},"content":{"rendered":"<p><img decoding=\"async\" loading=\"lazy\" class=\"wp-image-682 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/PS45.jpg\" alt=\"OLYMPUS DIGITAL CAMERA\" width=\"275\" height=\"353\" \/><\/p>\n<p>The <strong><span style=\"color: #ff0000;\">PS45<\/span> <\/strong>is a point level (on &#8211; off) pneumatic switch device used in conjunction with the KM26 Magnetic liquid level indicator, LS Series Cage Level switch or an External Chamber. The unique magnetic coupling action eliminates the need for such things as seals, diaphragms, springs or torque tubes.<\/p>\n<p><span style=\"color: #ff0000;\"><strong>Overview<\/strong><\/span><\/p>\n<div class=\"lo_cols t tab1\">\n<div class=\"lo_colsOut lo_2cols_1_67\">\n<div class=\"lo_colsIn lo_2cols_1in_67\">\n<div class=\"sf_cols\">\n<div class=\"sf_colsOut sf_1col_1_100\">\n<div id=\"Content_C048_Col00\" class=\"sf_colsIn sf_1col_1in_100 layout8\">\n<div class=\"sfContentBlock\">\n<p dir=\"LTR\" align=\"LEFT\">The PS45 is a point level (on &#8211; off) pneumatic switch device used in conjunction with the KM26 Magnetic liquid level indicator, LS Series Cage Level switch or an External Chamber. The unique magnetic coupling action eliminates the need for such things as seals, diaphragms, springs or torque tubes. Since process connections to the switch are eliminated, the user is insured complete isolation from the process. Valves are not required to block off the switch from the process for maintenance or operational testing. Preventive maintenance functions are greatly reduced since the switch never contacts the process fluid.<\/p>\n<p dir=\"LTR\" align=\"LEFT\"><span style=\"color: #ff0000;\"><strong>Data<\/strong><\/span><\/p>\n<\/div>\n<div class=\"lo_colsOut lo_2cols_1_67\">\n<div class=\"lo_colsIn lo_2cols_1in_67\">\n<div class=\"sf_cols\">\n<div class=\"sf_colsOut sf_1col_1_100\">\n<div id=\"Content_C049_Col00\" class=\"sf_colsIn sf_1col_1in_100 layout8\">\n<div class=\"sfContentBlock\">\n<ul>\n<li>Unique concept of magnetic coupling, eliminating direct contact with process<\/li>\n<li>Unique concept of magnetic coupling, eliminating direct contact with process<\/li>\n<li>No process piping or valves required<\/li>\n<li>Easy mounting and adjustment; only a small screwdriver required<\/li>\n<li>Action is field reversible<\/li>\n<li>Positive action &#8211; output is either zero or supply pressure, no intermediate values<\/li>\n<li>Vibration resistant<\/li>\n<li>Corrosion resistant construction<\/li>\n<li>No air or gas consumption required<\/li>\n<li>High reliability &#8211; minimal required maintenance<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><span style=\"color: #ff0000;\"><strong>Catalog and Questionnaire List<\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-677 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/DS_PS45-EN_G_01_2015.pdf.jpg\" alt=\"DS_PS45-EN_G_01_2015.pdf\" width=\"90\" height=\"120\" \/><\/p>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_PS45-EN_G_01_2015.pdf\" target=\"_blank\">Data sheet-DS_PS45-EN_G_01_2015<\/a><\/span><\/div>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><\/div>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\">\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_PS45-EN_F.pdf\" target=\"_blank\">Data sheet &#8211; PS45 &#8211; Magnetically Actuated No-Bleed Switch<\/a><\/span><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The PS45 is a point level (on &#8211; off) pneumatic switch device used in conjunction with the KM26 Magnetic liquid level indicator, LS Series Cage Level switch or an External Chamber. The unique magnetic coupling action eliminates the need for such things as seals, diaphragms, springs or torque tubes. Overview &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":526,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/692"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=692"}],"version-history":[{"count":2,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/692\/revisions"}],"predecessor-version":[{"id":702,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/692\/revisions\/702"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/526"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=692"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}