{"id":392,"date":"2020-12-19T10:35:09","date_gmt":"2020-12-19T10:35:09","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=392"},"modified":"2020-12-19T10:35:09","modified_gmt":"2020-12-19T10:35:09","slug":"fpd212-abb-dual-chamber-orifice-fitting","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=392","title":{"rendered":"FPD212 &#8211; ABB Dual chamber orifice fitting"},"content":{"rendered":"<p><a href=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-394 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212.jpg\" alt=\"FPD212\" width=\"400\" height=\"400\" srcset=\"https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212.jpg 400w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212-150x150.jpg 150w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212-300x300.jpg 300w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/FPD212-200x200.jpg 200w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a>FPD212 is dual-chamber orifice fitting, suitable for fiscal (custody transfer) applications. Subject to customer\u2019s own protocols, these fittings may enable orifice plates to be inspected and \/ or replaced without removing the fitting itself from the pipeline.<\/p>\n<p>The FPD212 dual-chamber orifice is a proven system for safely and quickly inspecting and changing orifice plates. Orifice meters used in the Oil &amp; Gas industry are typically of either the single-chamber or dual-chamber design.<br \/>\nSingle-chamber orifice fittings have an orifice plate that can be replaced without removing the fitting from the pipeline. However, before the plate can be withdrawn, the flow must be stopped and the pipeline vented.<br \/>\nDual chamber orifice fittings such as the FPD212 have an extra chamber into which the orifice plate is first withdrawn; this chamber is then isolated from the pipeline. This means that the flow in the pipeline does not necessarily have to be stopped to enable removal and refitting of the orifice plate and, although the second chamber must be vented, there is no requirement to vent the pipeline section.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"sfContentBlock\">\n<p>The FPD212 dual chamber fitting can \u2013 subject to the operator\u2019s own protocols \u2013 sometimes allow the orifice plate to be inspected or changed whilst the line is still pressurised.<br \/>\nHowever a safer and more industry-accepted meter to use in those situations is the FPD220 Double Block &amp; Bleed Dual chamber meter<br \/>\n<strong>The features of the FPD212 are :<\/strong><\/p>\n<ul>\n<li>High-pressure solution for up to ANSI 2500 rating<br \/>\nRated to 10,000 psi (698 bar)<\/li>\n<li>Maintenance can be performed at any time<br \/>\nNo need to wait for annual shutdown<\/li>\n<\/ul>\n<p><strong>Catalog and Questionnaire List<\/strong><\/p>\n<p><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_FPD212-EN_B.pdf\" target=\"_blank\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-393 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/12\/DS_FPD212-EN_B.pdf.jpg\" alt=\"DS_FPD212-EN_B.pdf\" width=\"90\" height=\"120\" \/><span class=\"dsTitle\">Data sheet &#8211; FPD212 Dual-chamber orifice fitting<\/span><\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>FPD212 is dual-chamber orifice fitting, suitable for fiscal (custody transfer) applications. Subject to customer\u2019s own protocols, these fittings may enable orifice plates to be inspected and \/ or replaced without removing the fitting itself from the pipeline. The FPD212 dual-chamber orifice is a proven system for safely and quickly inspecting &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":241,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/392"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=392"}],"version-history":[{"count":1,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/392\/revisions"}],"predecessor-version":[{"id":395,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/392\/revisions\/395"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/241"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}