{"id":262,"date":"2020-11-15T13:22:23","date_gmt":"2020-11-15T13:22:23","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=262"},"modified":"2020-11-15T13:22:23","modified_gmt":"2020-11-15T13:22:23","slug":"fcb130-and-fcb150-coriolis-mass-flowmeter-coriolismaster","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=262","title":{"rendered":"FCB130 and FCB150 &#8211; Coriolis mass flowmeter CoriolisMaster"},"content":{"rendered":"<p>CoriolisMaster FCB100 series of compact system integration flowmeters feature low pressure drop, high flow capacity, <img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-263 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA197988_400x400-300x300.jpg\" alt=\"9IBA197988_400x400\" width=\"300\" height=\"300\" srcset=\"https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA197988_400x400-300x300.jpg 300w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA197988_400x400-150x150.jpg 150w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA197988_400x400-200x200.jpg 200w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA197988_400x400.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>high speed RS485 Modbus communication and 2 digital outputs.<\/p>\n<p><span style=\"color: #000000;\"><strong>Overview<\/strong><\/span><\/p>\n<div class=\"lo_colsOut lo_2cols_1_67\">\n<div class=\"lo_colsIn lo_2cols_1in_67\">\n<div class=\"sf_cols\">\n<div class=\"sf_colsOut sf_1col_1_100\">\n<div id=\"Content_C048_Col00\" class=\"sf_colsIn sf_1col_1in_100 layout8\">\n<div class=\"sfContentBlock\">\n<p>With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.<\/p>\n<p>The FCB100 series\u00a0delivers:<\/p>\n<ul>\n<li>Superior accuracy and speed for filling applications<\/li>\n<li>Full parameter access with up to 115 kBaud<\/li>\n<li>Aluminum housing or all stainless steel solution<\/li>\n<li>DTM based diagnostic and operability functions<\/li>\n<\/ul>\n<p>The\u00a0sensor delivers:<\/p>\n<ul>\n<li>Multivariable measurement of mass flow, density and temperature in one device<\/li>\n<li>Low pressure drop save 25 % on pump energy costs compared to other brands<\/li>\n<li>Wide measurement span in a single meter<\/li>\n<\/ul>\n<p>FCB150 adds:<\/p>\n<ul>\n<li>DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement<\/li>\n<li>FillMass: Filling application software with integrated precounter, over- and underfill correction and contact output for valve control<\/li>\n<\/ul>\n<\/div>\n<div class=\"lo_cols t tab2\">\n<div class=\"lo_colsOut lo_2cols_1_67\">\n<div class=\"lo_colsIn lo_2cols_1in_67\">\n<div class=\"sf_cols\">\n<div class=\"sf_colsOut sf_1col_1_100\">\n<div id=\"Content_C049_Col00\" class=\"sf_colsIn sf_1col_1in_100 layout8\">\n<div class=\"textContainer headline\">\n<p class=\"tile-headline\"><span style=\"color: #000000;\"><strong>Data<\/strong><\/span><\/p>\n<\/div>\n<div class=\"sfContentBlock\">\n<p>General specifications:<\/p>\n<ul>\n<li>Nominal sizes \/ measuring ranges<br \/>\n\u2013 DN 15 (1\/2 in.) \/ 0 to 8,000 kg\/h (17,637 lb\/h)<br \/>\n\u2013 DN 25 (1 in.) \/ 0 to 35,000 kg\/h (77,162 lb\/h)<br \/>\n\u2013 DN 50 (2 in.) \/ 0 to 90,000 kg\/h (198,416 lb\/h)<br \/>\n\u2013 DN 80 (3 in.) \/ 0 to 250,000 kg\/h (551,156 lb\/h)<br \/>\n\u2013 DN 100 (4 in.) \/ 0 to 520,000 kg\/h (1,146,404 lb\/h)<br \/>\n\u2013 DN 150 (6 in.) \/ 0 to 860,000 kg\/h (1,895,975 lb\/h)<\/li>\n<li>Ex approvals<br \/>\n\u2013 ATEX zone 0\/1\/2, cFMus Div 1\/2 and zone 0\/1\/2<\/li>\n<li>Wetted materials<br \/>\n\u2013 1.4404 \/ 1.4435 (316L) or Hasteloy C<\/li>\n<li>Accuracy\u00a0for liquids<br \/>\nFCB130<br \/>\n\u2013 Mass and volume: 0.4 % o. r. \/ 0.25 % o. r.<br \/>\n\u2013 Density: 10 g\/l<br \/>\nFCB150<br \/>\n\u2013 Mass: 0.15 % o. r. \/ 0.1 % o. r., volume: 0.15 % o. r.<br \/>\n\u2013 Density:\u00a02 g\/l or 1 g\/l<\/li>\n<li>Measuring medium temperature<br \/>\nFCB130<br \/>\n\u2013\u00a0 -50 to 160 \u00b0C (-58 to 320 \u00b0F)<br \/>\nFCB150<br \/>\n\u2013\u00a0 -50 to 205 \u00b0C (-58 to 400 \u00b0F)<\/li>\n<li>Outputs<br \/>\n\u2013 2 digital out (pulse, frequency, contact)<br \/>\n\u2013 Modbus<\/li>\n<li>Power supply<br \/>\n\u2013 11 to 30\u00a0V DC<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"lo_colsOut lo_2cols_2_33\"><strong>\u00a0Catalog and Questionnaire List<\/strong><\/div>\n<div class=\"lo_colsOut lo_2cols_2_33\"><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-252 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/DS_FCB400_FCH400_EN_K.pdf.jpg\" alt=\"DS_FCB400_FCH400_EN_K.pdf\" width=\"90\" height=\"120\" \/><\/p>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_FCB100_FCH100_EN_H.pdf\">Data sheet &#8211; CoriolisMaster FCB130, FCB150, FCH130, FCH150 | Coriolis mass flowmeter<\/a><\/span><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>CoriolisMaster FCB100 series of compact system integration flowmeters feature low pressure drop, high flow capacity, high speed RS485 Modbus communication and 2 digital outputs. Overview With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before. The FCB100 series\u00a0delivers: &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":235,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/262"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=262"}],"version-history":[{"count":1,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/262\/revisions"}],"predecessor-version":[{"id":264,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/262\/revisions\/264"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/235"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}