{"id":251,"date":"2020-11-15T12:54:47","date_gmt":"2020-11-15T12:54:47","guid":{"rendered":"http:\/\/abb.quad-industry.com\/?page_id=251"},"modified":"2020-11-15T12:54:47","modified_gmt":"2020-11-15T12:54:47","slug":"fcb430-and-fcb450-coriolis-mass-flowmeter-coriolismaster","status":"publish","type":"page","link":"https:\/\/abb.quad-industry.com\/?page_id=251","title":{"rendered":"FCB430 and FCB450 &#8211; Coriolis mass flowmeter CoriolisMaster"},"content":{"rendered":"<p><span style=\"color: #ff0000;\"><strong>CoriolisMaster FCB400 <\/strong><\/span>series of compact Coriolis mass flowmeters feature low pressure drop, high capacity, <img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-236 alignright\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA195751_400x400-300x300.jpg\" alt=\"9IBA195751_400x400\" width=\"300\" height=\"300\" srcset=\"https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA195751_400x400-300x300.jpg 300w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA195751_400x400-150x150.jpg 150w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA195751_400x400-200x200.jpg 200w, https:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/9IBA195751_400x400.jpg 400w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>intuitive ABB common display, five modular I\/O`s and HART communication.<\/p>\n<p><span style=\"color: #000000;\"><strong>Overview<\/strong><\/span><\/p>\n<div class=\"sfContentBlock\">\n<p>With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.<\/p>\n<p><strong>The FCB400 series\u00a0delivers:\u00a0<\/strong><\/p>\n<ul>\n<li>Up to five modular I\/Os<br \/>\n\u2013\u00a0Multivariable meter design<br \/>\n\u2013\u00a0Optional plug-in cards<br \/>\n\u2013\u00a0Automatic firmware update<\/li>\n<li>SmartSensor<br \/>\n\u2013\u00a0All digital solution<br \/>\n\u2013\u00a0Installation flexibility<br \/>\n\u2013\u00a0Meter intelligence located in the sensor<\/li>\n<li>SensorApplicationMemory<br \/>\n\u2013\u00a0Maximum data security<br \/>\n\u2013\u00a0Plug and play electronics replacement<\/li>\n<li>ABB common look and feel<br \/>\n\u2013\u00a0Easy Set-up<br \/>\n\u2013\u00a0Operation through the glass via capacitive keys<\/li>\n<li>VeriMass on-board verification and diagnostics<br \/>\n\u2013\u00a0Online preventive maintenance<br \/>\n\u2013\u00a0Extended maintenance cycles<br \/>\n\u2013\u00a0Reduced maintenance effort<\/li>\n<li>Designed for 70 \u00b0C (158 \u00b0F) ambient temperature and high vibrations<\/li>\n<li>Lower pressure drop<\/li>\n<li>Self-draining<\/li>\n<li>Global approvals for explosion protection<\/li>\n<\/ul>\n<p><strong>The FCB450 adds:<\/strong><\/p>\n<ul>\n<li>DensiMass software for direct concentration measurement<\/li>\n<li>FillMass software for filling application control<\/li>\n<\/ul>\n<div class=\"sfContentBlock\">\n<p>&nbsp;<\/p>\n<p><span style=\"color: #000000;\"><strong>Data<\/strong><\/span><\/p>\n<p>General specifications:<\/p>\n<ul>\n<li>Nominal sizes \/ measuring ranges<br \/>\n\u2013 DN 15 (1\/2 in.) \/ 0 to 8,000 kg\/h (17,637 lb\/h)<br \/>\n\u2013 DN 25 (1 in.) \/ 0 to 35,000 kg\/h (77,162 lb\/h)<br \/>\n\u2013 DN 50 (2 in.) \/ 0 to 90,000 kg\/h (198,416 lb\/h)<br \/>\n\u2013 DN 80 (3 in.) \/ 0 to 250,000 kg\/h (551,156 lb\/h)<br \/>\n\u2013 DN 100 (4 in.) \/ 0 to 520,000 kg\/h (1,146,404 lb\/h)<br \/>\n\u2013 DN 150 (6 in.) \/ 0 to 860,000 kg\/h (1,895,975 lb\/h)<\/li>\n<li>Ex approvals<br \/>\n\u2013 ATEX zone 0\/1\/2, cFMus Div 1\/2 and zone 0\/1\/2<\/li>\n<li>Wetted materials<br \/>\n\u2013 1.4404 \/ 1.4435 (316L) or Hasteloy C<\/li>\n<li>Accuracy\u00a0for liquids<br \/>\nFCB430<br \/>\n\u2013 Mass and volume: 0.4 % o. r. \/ 0.25 % o. r. \/ 0.2 % o. r.<br \/>\n\u2013 Density: 10 g\/l<br \/>\nFCB450<br \/>\n\u2013 Mass: 0.15 % o. r. \/ 0.1 % o. r., volume: 0.15 % o. r.<br \/>\n\u2013 Density:\u00a02 g\/l or 1 g\/l<\/li>\n<li>Measuring medium temperature<br \/>\nFCB430<br \/>\n\u2013\u00a0 -50 to 160 \u00b0C (-58 to 320 \u00b0F)<br \/>\nFCB450<br \/>\n\u2013\u00a0 -50 to 205 \u00b0C (-58 to 400 \u00b0F)<\/li>\n<li>Outputs<br \/>\n\u2013\u00a05 modular I\/Os<br \/>\n\u2013 HART 7.1<br \/>\n\u2013 PROFIBUS DP<br \/>\n\u2013 Modbus<\/li>\n<li>Power supply<br \/>\n\u2013 11 to 30 V DC, 110\/230 V AC<\/li>\n<\/ul>\n<p><span style=\"color: #000000;\"><strong>Catalog and Questionnaire List<\/strong><\/span><\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-full wp-image-252 alignleft\" src=\"http:\/\/abb.quad-industry.com\/wp-content\/uploads\/2020\/11\/DS_FCB400_FCH400_EN_K.pdf.jpg\" alt=\"DS_FCB400_FCH400_EN_K.pdf\" width=\"90\" height=\"120\" \/><\/p>\n<div class=\"dsDocumentData dsDocumentDataThumbnail\"><span class=\"dsTitle\"><a href=\"http:\/\/abb.quad-industry.com\/pdf\/DS_FCB400_FCH400_EN_K.pdf\">Data sheet &#8211; CoriolisMaster FCB430, FCB450, FCH430, FCH450 | Coriolis mass flowmeter<\/a><\/span><\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>CoriolisMaster FCB400 series of compact Coriolis mass flowmeters feature low pressure drop, high capacity, intuitive ABB common display, five modular I\/O`s and HART communication. Overview With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before. The FCB400 &hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":235,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/251"}],"collection":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=251"}],"version-history":[{"count":1,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/251\/revisions"}],"predecessor-version":[{"id":253,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/251\/revisions\/253"}],"up":[{"embeddable":true,"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=\/wp\/v2\/pages\/235"}],"wp:attachment":[{"href":"https:\/\/abb.quad-industry.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=251"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}